Home Consumer Electronics Anti-Reflection Coating RFQs: Specify the Working Angle and Polarization

Anti-Reflection Coating RFQs: Specify the Working Angle and Polarization

Inquiry
  • Description

An anti-reflection coating specified only as “visible AR” leaves a supplier guessing about the performance that matters. A window that works close to normal incidence and a lens that receives a steep ray cone can need different acceptance conditions, even if both are used at the same wavelengths. Put those conditions into the request for quotation before comparing prices.

Define performance where the optic actually works

List the wavelength interval and the operating angles relative to the local surface normal. For a converging beam, provide the nominal direction and cone range rather than a single central ray. On a curved part, indicate whether the acceptance angle is a ray-trace requirement or a specific measurement condition agreed for inspection.

State the polarization assumptions. If the system uses a defined linear polarization, tell the supplier how it is oriented relative to the plane of incidence. If performance matters for both s and p, request both curves or separate limits. “Unpolarized” should describe the intended measurement or model, not replace an explicit requirement when one polarization can drive failure.

Describe the acceptance metric

  • Specify whether the limit is peak or average reflectance, over a band or at named wavelengths.
  • State whether it applies to each coated surface or to the complete optic. End-to-end transmission also includes effects of other surfaces and the substrate.
  • Identify the substrate grade, coated side, clear aperture and masking boundary. Mark surfaces on the drawing instead of relying on phrases like “front side.”
  • Call out any environmental tests separately and say whether spectral performance is measured before or after them.

Agree on what a witness sample can show

A flat witness can help track a coating run when the purchased part is difficult to measure directly. Ask how the sample relates to the part: material, fixture position, run identity and measurement geometry should be documented. If the part is curved, do not treat the witness curve alone as proof of performance everywhere on that part. Decide up front which results require an actual component or a system-level test.

Send a marked drawing and a small table of wavelengths, angles, polarization states and limits. A supplier can then distinguish routine reporting from measurements that require a separate fixture or qualification step.

Technical background: Edmund Optics’ introduction to optical coatings.