WhatsApp: +86 13530516428 Tel: 0755-23089686     sales@silveroptics.net

Consumer Electronics

Home Consumer Electronics Beamsplitter RFQ: Define the Ratio at the Operating Conditions

Beamsplitter RFQ: Define the Ratio at the Operating Conditions

Inquiry
  • Description

A 70/30 marking does not tell a supplier which port should receive more power or under what conditions to verify it. Define the reflected and transmitted paths in a sketch, then specify how to measure the ratio.

Label the Beam Paths

Mark the input, the transmitted port, and the reflected port. Identify the input face, nominal incidence geometry, and effective beam diameter. For a plate or cube substitution, ask for a revised interface drawing before accepting it. Mechanical fit alone does not establish an equivalent beam path.

Define the Measurement

Specify wavelength or band and input polarization. Decide whether acceptance is evaluated at a single condition or across a range. If collected power matters, state minimum power at the ports or define the loss budget. A ratio between outputs does not establish total throughput.

RFQ Checklist

  • Port and input-face diagram
  • Wavelength, incidence geometry, and polarization
  • Ratio convention, tolerance, and throughput requirements

Any cosmetic acceptance requirement should separately explain how to inspect for scratches and digs.